Building Materials and Techniques

The types of building materials used affect a home's longevity. The Solar Energy Cottage incorporates the use of sustainable building materials and techniques including:

  • Engineered wood products stretch wood resources, are structurally superior, and can be made from new growth trees
  • Fibrous cement siding made from natural materials is durable and requires little maintenance
  • Recycled carpet with low volatile organic compound (VOC) content improves indoor air quality

Structural insulated panels (SIPs) used for the exterior walls and ceiling allow for quick construction and ensure proper installation of insulation
Building materials used to increase the home's durability by preventing moisture problems that can lead to mold growth include:
  • French drain around exterior perimeter of footer
  • 6-mil polyethylene covering crawlspace floor and sealed to walls
  • Capillary break installed between foundation walls and framed floor to prevent wicking of water
  • Housewrap properly installed on the exterior of all above grade walls
  • Overhangs above all doors and most windows
  • Quiet bath fan vented to the exterior and featuring low sone ratings of 0.5 sone at 50 cubic feet per minute (cfm) to 3.0 sones at 340 cfm
  • No combustion appliances

Recycled content porch decking is easy to use and reduces landfill waste

Foundation walls covered along the interior with rigid foam insulation to prevent condensation

Back to top

Air Sealing

A "leaky" home causes high energy costs, poor comfort, and promotes entry of moisture and contaminants. Unfortunately many sites for air leakage are hidden from view. The best strategy in both new and existing homes is to reduce air leakage as much as possible and to provide controlled ventilation with fresh outdoor air.

  • The SIPs (explained above) provided a solid building envelope to begin with. Additional air sealing was required:
    - Behind shower on exterior wall
    - Around door and window rough openings
    - In penetrations on the exterior of the SIPs and in crawlspace walls
    - At bottom plates between the concrete foundation or subfloor and wood framing
    - Along edges of plastic floor cover in crawlspace
  • Weatherstripping was applied on all exterior windows and doors

Insulation

The Solar Energy Cottage features a mix of insulation types to minimize heat transfer through the walls, ceilings and floors.

  • Insulation for the walls (R-22.6) and ceiling (R-38) is integrated in the SIPs during production
  • R-5 foam board insulation along crawlspace walls

Crawlspace

The standard crawlspace building practice is to insulate underneath floors over unconditioned and vented crawlspaces. However, unconditioned and vented crawlspaces typically cause comfort and moisture problems in the southeast. Studies have proven that conditioning and insulating the walls of well-sealed crawlspaces can be an effective alternative to the standard building practice.


R-5 spray foam insulation in band area

The construction of the Solar Energy Cottage conditioned crawlspace consists of:

  • Poured footer with, CMU blocks stacked on top, reinforced, and filled with more concrete
  • Foundation drain installed around the perimeter of the footer (as opposed to on top of the footer) keeps excess water from soaking the footer
  • Damproofing on exterior sides of crawlspace walls
  • 6-mil polyethylene covering the floor with sealant applied to all seems and the edges turned up and sealed to the walls
  • Band area sprayed with expanding polystyrene (R-5) to further insulate and seal cracks and penetrations.
Back to top


Supply vent to condition crawlspace and to maintain a positive pressure in the crawlspace


1 inch extruded polystyrene board with an R-value of 7.5, applied to the interior walls beginning four inches above grade (to allow for termite inspection) and continuing to the floor joist bottoms.

Heating, Cooling and Ventilation

On average 41% of a home's energy usage can go to conditioning (heating and cooling) the house. Determining the correct size of heating and cooling equipment is key to achieving comfortable interior conditions -- temperature and humidity -- and for saving on the costs to buy and operate equipment.

  • 14 SEER heat pump with a heating season performance factor (HSPF) of 8.95 and a variable speed blower provides high efficiency heating and cooling
  • Programmable thermostat allows different temperature settings during the day, evening, and weekend to save energy
  • All duct work is insulated, located within conditioned space and
  • all connections are sealed with mastic reducing duct leakage to less than 5%

Fresh air ventilation controlled by a whole house dehumidifier keeps the cottage drier and occupants more comfortable at higher temperatures

Lighting

Every $1 spent on electricity for an incandescent bulb, provides 10¢ worth of light and 90¢ worth of heat. The wasted energy increases lighting and air conditioning costs and is responsible for over 500 pounds of atmospheric pollution.

Back to top


Compact fluorescent light (CFL) fixtures and CFL bulbs in traditional light fixtures featured in the Solar Cottage, replace traditional incandescent lighting and reduce the amount of energy used for lighting by 45%

Indoor Water Conservation

Atlanta, like many communities, is facing a water crisis. Water efficient fixtures save money, provide high performance, and protect the environment.

  • All shower and sink fixtures have low flows of 2.25 gal/minute or less

Water Heater

Water heating is the third highest energy cost in a home representing 16% of total energy cost on average. Selecting the appropriate fuel and water heater type, using efficient system deign, and reducing hot water consumption can manage water-heating energy costs.


The Solar Energy Cottage displays one 50-gallon super high efficiency electric water heater with an energy factor of 0.94

Windows

The Georgia Energy Code encourages that windows and glass doors used have a solar heat gain coefficient (SHGC) less than 0.4 and a U-factor of 0.65 or less. The SHGC is a measure of the amount of solar heat (heat radiating from the sun) that an object blocks. U-factor measures the amount of heat conducted through a material. U-factor is the inverse of the R-value. The lower the U-factor, or the higher the R-value, the more efficient the window will be.

  • All windows are Low E II with argon fill gas and have a U-factor of 0.31 and a SHGC of 0.30
Back to top

Photovoltaic System

Photovoltaic (PV) systems silently generate electricity from free sunlight. The Solar Energy Cottage demonstrates how PV systems can offset the amount of electric power needed from conventional power plants to improve air quality and reliability.

The Solar Energy Cottage displays:

  • A 4kW grid connected photovoltaic system expecting to supply approximately 67% of the building's electricity needs
Back to top